Instrumentation
Weighing digital instrumentation

 
DAT 400

Weighing digital/analog transmitter for load cells. 6-digit red LED display, 7-segment, 14 mm high. Display resolution 60,000 counts. 2 relay logic outputs; 2 opto-isolated logic inputs. Serial output: RS232 or RS 422/RS485, ASCII, MODBUS RTU protocol. Optional 16 bit analog outputs: 0-20 mA, 4-20 mA, 0-5 V, 0-10 V. Optional fieldbus outputs: Profibus-DP or DeviceNet. Supply voltage 24 Vdc. "Snap-on" DIN rail mounting.


 
DAT 450

Digital/analog transmitter, same as DAT 400, but without display. Saving money solution but,with the same superior technical specifications, good for certain plant applications.


 
DAT 500

Digital/analog transmitter same as the model DAT 400, but with panel mounting case.


 
DAT-S 400

Digital/analog transmitter same ase the models DAT 400, with ATEX IP 65 stainless steel box and safe external Electrical connections IP67 M12 the benefit of wich are: No need to open the sealed box in order to connect and disconnect the cables, avoid any missconnection by accident.


 
GATEWAY 300 COMUNICATOR

Gateway to fieldbus. Protocols converter for transferring weight data from DAT series transmitters to PC or PLC. Can accept up to 25 DAT series transmitters. Available interfaces: Profibus DP, DeviceNet, CANopen, ControlNET, TCP/IP, Modbus Plus.Profibus DP, DeviceNet, CANopen, ControlNET, TCP/IP, Modbus Supply voltage 24 Vdc. "Snap-on" DIN rail mounting.


 
LC 200

Electronic overload guard model LC 200. 6-digit red LED display, 14 mm high. Display resolution from 500 to 100,000 counts. 3 relay logic outputs; 1 opto-isolated logic input. Serial output: RS 232 or RS485. Supply voltage 12-24 Vdc. "Snap-on" DIN rail mounting.


 
MC 102

Weight digital indicator for load cells model MC 102.
6-digit red LED display, 14 mm high.
Display resolution 99,999 counts.
4 relay logic outputs; 3 opto-isolated logic inputs.
2 independent serial outputs: RS232 and RS422/RS485, ASCII MODBUS RTU protocol.
Optional 16 bit analog output: 0-20 mA, 0-5 V, 0-10 V.
Supply voltage 230 Vac +/-10% (optional 115 Vac), 50/60 Hz.
Panel mounting.



 
MC 302

Weight indicator and batching controller for load cells model MC 302.
7-digit red LED display, 14 mm high.
Display resolution 600,000 counts (10,000 for legal for trade version).
6 relay serial outputs; 8 opto-isolated logic inputs.
2 independent serial outputs: RS232 and RS422/RS485, ASCII, MODBUS RTU protocol.
Optional analog output: 0-20 mA, 4-20 mA, 0-5 V, 0-10 V.
Batching up to 4 ingredients (batch-in with intermediate batch-out), or batch-out of 1 ingredient.
Supply voltage 230 Vac +/-10% (optional 115 Vac), 50/60 Hz.
Panel mounting.



 
MC S 302

The MC-S 302 is the same as the MC 302, but with IP 65 and ATEX stainless steel box and safe external Electrical connections IP67 M12 the benefit of which are: no need to open the sealed box in order to connect and disconnect the cables, avoid any missconnection by accident.


 
MC-S 102

Same as MC 102, but with IP65 stainless steel BOX and safe external electrical connections IP67 M12 the benefit of which are: no need to open the sealed box in order to connect and disconnect the cables, avoid any missconnection by accident.



 
UWT 600

Industrial universal weight transmitter for load cells. Alphanumeric LCD display, 2 rows of 16 characters, 5 mm high. Display resolution 600,000 counts. Possibility to set the 4 different sensibilities of 4 load cells and not the average. 2 independent serial outputs: RS 232 and RS 422/RS 485, ASCII or Modbus RTV protocol. Optional versions with analog output, 2 inputs and 2 logic outputs. Optional protocols: Profibus-DP, DeviceNet or Ethernet. Supply voltage 24 Vdc.


 
UWT 600/I I BOX 2000/4

The UWT 600/I universal weight transmitter and I Box 2000/4 Intelligent digital junction box Combination, for weighing systems with 2, 3, or 4 analog load cells.
It gives high advantages on the installation, calibration, failures analysis, emulation (compensation for load cell failure), servicing.
Optional versions with analog output and Profibus-DP or Ethernet.


Weighing analog instrumentation

 
AT-08

Load cell signal conditioner. Selectable input signals: 10 mV, 20 mV, 30 mV. Outputs: 0-10 V or 4-20 mA. Supply voltage 24 Vdc (115/230 Vac optional). "Snap-on" DIN rail mounting.


 
AT-10

Load cell signal conditioner. 20-pole terminal block for direct connection of up to 4 load cells (without junction box). Input signal: from 3 mV up to 30 mV. Outputs: 0-5 V, 0-10 V, 4-20 mA. Supply voltage 24 Vdc (115/230 Vac optional). "Snap-on" DIN rail mounting.

Remote displays and accessories

 
CGS 4/C - CEM 4/C

Junction summing boxes model CGS 4/C and CEM 4/C, for up to 4 load cells max.
Versions in cast aluminum, in ABS plastics or in stainless steel. Degree of protection IP66 (model CGS 4/C), IP65 (model CEM 4/C).
Available as a printed circuit board only.
Designed to permit a quick connection between the 1006 model Tester and the load cells (see our 1006 model Tester - item "Instrumentation - Remote displays and accessories/Junction boxes").


 
REM 20 - REM 60 - REM 100 - REM 160

Red LED remote display with digits respectively 20 mm (REM 20), 60 mm (REM 60), 100 mm (REM 100) and 160 mm (REM 160) high.
Reading distance of respectively 8 m, 15 m, 35 m and 40 m about.
Serial inputs RS232 and RS 422/RS 485.
Supply voltage 110รท240 V, 50/60 Hz; for REM 20: 115 or 230 Vac, 50/60 Hz.
Case in stainless steel - protection IP 65 and, for REM 20 only, in ABS plastics.
On request, optional 4-20 mA analog input.



 
TESTER 1006

The TESTER model 1006 displays at the same time up to 4 mV/V signals and/or the weights and/or the weight values on each cell, thus enabling the service engineer to verify for the correct weight distribution, or overload, or failure on one or more load cells, or possible mistakes in the electrical connection.
It makes easy the system or load cells failures diagnosis.
Palm portable: 500 g about weight.
Suitable for any weighing system. If used with our junction boxes, it permits a quick connection.
Complete of the Calibration function, useful to generate mV/V signals for the instruments calibration.

Junction boxes

 
CGS 4/C - CEM 4/C

Junction summing boxes model CGS 4/C and CEM 4/C, for up to 4 load cells max.
Versions in cast aluminum, in ABS plastics or in stainless steel. Degree of protection IP66 (model CGS 4/C), IP65 (model CEM 4/C).
Available as a printed circuit board only.
Designed to permit a quick connection between the 1006 model Tester and the load cells (see our 1006 model Tester - item "Instrumentation - Remote displays and accessories/Junction boxes


 
CGS 4/S - CGS 8

Junction summing boxes for 4 (or 8) load cells max. CGS 4/S: "small" version of the CGS 4 for 4 load cells. CGS 8: version for 8 load cells. Cast aluminum. CGS 4/S available as ATEX version. Degree of protection IP65. Dimensions: 125x80xh60 mm (CGS 4/S); 230x200xh110 mm (CGS 8).


 
I BOX 2000/4

Intelligent digital junction board. Economical effective alternative to the digital load cells. Replaces the analogue junction boxes. Permits to monitor the mV/V sensitivity of each load cell connected to it. Allows to correct any error due to the damaged load cells, when used together with the UWT 600/I transmitter. 2 serial ports: RS 232 and RS 485. Available as board only or mounted into an aluminum or plastic ABS box. Special antiflame 6-wire PVC cables available for connection between the junction board and the instrumentation.


 
TESTER 1006

WITH A UNIQUE COMBINATION OF FEATURES AND CONNECTING FLEXIBILTY, the TESTER model 1006 displays at the same time up to 4 mV/V signals and/or the weights and/or the weight values on each cell, thus enabling the service engineer to verify for the correct weight distribution, or overload, or failure on one or more load cells, or possible mistakes in the electrical connection.
It makes easy the system or load cells failures diagnosis.
Palm portable: 500 g about weight.
Suitable for any weighing system. If used with our junction boxes, it permits a quick connection.
Complete of the Calibration function, useful to generate mV/V signals for the instruments calibration.

Calibrators

 
TESTER 1006

WITH A UNIQUE COMBINATION OF FEATURES AND CONNECTING FLEXIBILTY, the TESTER model 1006 displays at the same time up to 4 mV/V signals and/or the weights and/or the weight values on each cell, thus enabling the service engineer to verify for the correct weight distribution, or overload, or failure on one or more load cells, or possible mistakes in the electrical connection.
It makes easy the system or load cells failures diagnosis.
Palm portable: 500 g about weight.
Suitable for any weighing system. If used with our junction boxes, it permits a quick connection.
Complete of the Calibration function, useful to generate mV/V signals for the instruments calibration.


 
Pavone Sistemi S.r.l. - via Dei Chiosi, 18 - 20040 Cavenago Brianza (MI) Italy